15S/16S Lithium Battery Management System (BMS)Characteristic performance: storage, anti-backconnection, display batt...
Main parameter

Product type: 3U communication backup power supply lithium battery protection board

Specification: 4850-48100

Main board size: 260mm*100mm*35mm

Suitable Series Number: 9-16 Series

Temperature detection point: 4 routes (16 routes can be achieved)

Continuous discharge current: 100A

Charging Current Limitation: 5A/10A/20A (optional)

Working Temperature: - 20 ~70 65507

Others: with pre-charging function, CAN communication, dry contacts, display screen, parallel function


communication back-up power Lithium battery manamgement system

Product introduction
Characteristic performance: storage, anti-backconnection, display battery status, communication interface, light-load...
Main parameter

Product type: 2U communication backup power supply lithium battery protection board

Specification: 4850

Main board size: 260mm*80mm*35mm

Suitable Series Number: 9-16 Series

Temperature detection point: 4 routes (16 routes can be achieved)

Continuous discharge current: 50A

Charging Current Limitation: 5A/10A/20A (optional)

Working Temperature: - 20 ~70 65507

Others: with pre-charging function, CAN communication, dry contacts, display screen, parallel function

15S/16S Lithium Battery Management System (BMS)


communication back-up power Lithium battery manamgement system

Product introduction
Characteristic performance: storage, anti-backconnection, display battery status, communication interface, light-load...
Main parameter

Product Type: 1U Communication Backup Power Supply Lithium Battery Protection Board

Specification: 4810, 4820

Main board size: 254mm*38mm*30mm

Suitable Series Number: 9-16 Series

Temperature detection point: 4 routes (16 routes can be achieved)

Continuous discharge current: 20A

Charging Current Limitation: 2A

Working Temperature: - 20 ~70 65507

Other: Dry Contact, Parallel Function